Owner's Guide
Printed in China
Toll Free 1 866 295 6775
ww
w.PowerBright.com
WARNING:
This Unit employs Components that tend to produce arcs or sparks – To
prevent fire or explosion, do not install in compartments containing
batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.
CAUTION:
OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral
protection against overloads. To prevent fire, do not cover or obstruct
ventilation openings. Do not mount in Zero-Clearance compartment.
Overheating may result.
Notice :
The output of this device is not sinusoidal. It has a total harmonic distortion
of 30% percent and maximum single harmonic of 8 percent
XC120
XC180
Conforms to / Conforme à UL std. 458,
CSA std. C22.2 No. 107.1
Vista de página 0
1 2 3 4 5 6 ... 22 23

Resumo do Conteúdo

Página 1 - Owner's Guide

Owner's Guide Printed in ChinaToll Free 1 866 295 6775www.PowerBright.comWARNING:This Unit employs Components that tend to produce arcs or spark

Página 2 - 1 Introduction

96 Inverter Operation1.When properly connected to a 12V outlet, the light will glow GREEN, indicating the inverter is ready.2. Plug the product(s) y

Página 3 - Warnings and Cautions

10• If an AC product rated higher than 120/180 is plugged into the XC120/180, the inverter will shut down. The LED light will alternate fromGREEN to

Página 4 - CAUTION: Risk of Fire

11• In the event of an overload, low battery voltage oroverheating, the XC120 / XC180 automaticallyshuts down.Battery Operating TimeOperating time wil

Página 5 - XC120/XC180

12Interference with Electronic EquipmentGenerally, most AC products operate withXC120/180just as they would with household AC power.Below is informati

Página 6 - 3 Safety Features

137 TroubleshootingPROBLEM: AC product will not operate, no inverterlights are ON.PROBLEM: Measured inverter output is to o low.Possible cause Solutio

Página 7 - 4 Inverter Features

14PROBLEM: AC product will not operate, RED light ON.Battery voltage is too low. Recharge battery.Possible cause SolutionAC product(s) connecte

Página 8 - 5 Using the In verter

15Specifications are subject to change without notice.AC Powe r OutputAC output voltage (nominal)Continuous AC output powerMaximum AC output surge pow

Página 9

16DC PowerPhysicalDC input voltage range (VDC)13.8V DC, 10A Max 13.8V DC, 15A MaxBattery drain with no AC load (at 12 V input)0.4AEfficiency (maximum)

Página 10 - 6 Inverter Operation

179 Warranty and ReturnWarrantyWhat does this warranty cover?This Limited Warrantyis provided by PowerBright andcovers defects in workmanship and mate

Página 11 - XC120/180

18shipment to the customer, whichever is greater. All replacedproducts and all parts removed from repaired productsbecome the property of PowerBright.

Página 12 - Battery Operating Time

2 Important Safety InformationMisusing or incorrectly connecting themay damage the equipment or create hazardousconditions for users. Read the followi

Página 13 - XC120/18

19What does this warranty not cover? Th is LimitedWarranty does not cover normal wear and tear of the productor costs related to the removal, installa

Página 14 - 7 Troubleshooting

20ExclusionsIf this product is a consumer product, federal law does notallow an exclusion of implied warranties. To the extent youare entitled to impl

Página 15 - AC product(s) connected

21Return Material Authorization PolicyBefore returning a product directly to PowerBright you mustobtain a Return Material Authorization (RMA) number a

Página 16 - AC Powe r Output

22Return Procedure1. Package the unit safely, preferably using the originalbox and packing materials. Please ensure that yourproduct is shipped fully

Página 17 - DC Power

2The housing may becomeuncomfortably warm, reaching 140° F (60° C) underextended high power operation. During operation,keep it away from materials th

Página 18 - 9 Warranty and Return

3CAUTION: Risk of Fire.Do not replace any vehicle fuse with a rating higher than recommended by the Vehicle Manufacturer.Ensure that the electrical sy

Página 19

4CAUTION: Output non-sinusoidalSome chargers for small nickel-cadmium batteriescan be damaged if connected to theDo not use the inverter with the foll

Página 20

5Additional Safety Guidelines• Do not insert foreign objects in theoutlets or other openings.• Never connect the inverter to power utility ACdistribut

Página 21 - Warning: L imitations On Use

64 Inverter FeaturesPowerBright®USB port 2.1 AmpLED LightindicatorAC OutletDC ConnectorVentilation openingsXC120/180(shared)

Página 22

75 Using the In verterThrough its AC outlet, the is capable of powering most 120V AC products that use120W/180W or less. The can also

Página 23 - Return Procedure

81. Plug a DC cable into the DC cable port on theXC120/180 and connect to a 12V cigarette lighterreceptacle.2. Plug the device you want to operate

Modelos relacionados XC120

Comentários a estes Manuais

Sem comentários